Power supply model | LZ11-0.5K | LZ11-1K | LZ11-3K | LZ11-5K | LZ11-10K | |
Rated capacity | 500VA | 1KVA | 3KVA | 5KVA | 10KVA | |
Circuit diagram | IGBT/PWM Pulse Width Modulation Method | |||||
Enter | Ph.Num | 1- Phase | ||||
Volt | 220V±10% | |||||
Freq | 50Hz/60Hz±10% | |||||
Output | Ph.Num | 1- Phase | ||||
Wfm | Pure Sine Wave | |||||
Rated Volt | 115V | |||||
Adj.Range | 0-150VContinuously Adjustable | |||||
Load Reg.Rate | ≤1% | |||||
Rated Freq | 400Hz | |||||
Adj.Range | 300Hz-500Hz Continuously Adjustable (Custom frequencies available) | |||||
Freq.Stab | Rated Frequency ≤0.1%; Adjustment Range ≤0.01% | |||||
Wfm.Dist (THD) | THD≤3% | |||||
Eff | ≥80%(100%Load) | |||||
Resp.Time | ≤2ms | |||||
Suit.Load | No load type restrictions, but motors and rectifying loads require derating. | |||||
Display | High-precision four-digit digital LED display for voltage, current, frequency, power, and power factor | |||||
Cooling method | Fan Cooling | |||||
Noise level | ≤55dB | |||||
Output protection | Complete protection functions and alarm devices for overvoltage, overcurrent, short circuit, and overheating. | |||||
Reliability | MTBF | 1.0×105h | ||||
MTTR | 0.5h | |||||
Env | Work.Temp | -25℃-55℃ | ||||
Rel.Hum | 0-90% (non-condensing) | |||||
Altitude | ≤2000 meters | |||||
Power supply model | LZ31-15K | LZ31-20K | LZ31-30K | LZ31-60K | LZ31-100K | |
Rated capacity | 15KVA | 20KVA | 30KVA | 60KVA | 100KVA | |
Circuit diagram | IGBT/PWM Pulse Width Modulation Method | |||||
Enter | Ph.Num | 3- Phase | ||||
Volt | 380V±10% | |||||
Freq | 50Hz/60Hz±10% | |||||
Output | Ph.Num | 1- Phase | ||||
Wfm | Pure Sine Wave | |||||
Rated Volt | 115V | |||||
Adj.Range | 0-150VContinuously Adjustable | |||||
Load Reg.Rate | ≤1% | |||||
Rated Freq | 400Hz | |||||
Adj.Range | 300Hz-500Hz Continuously Adjustable (Custom frequencies available) | |||||
Freq.Stab | Rated Frequency ≤0.1%; Adjustment Range ≤0.01% | |||||
Wfm.Dist (THD) | THD≤3% | |||||
Eff | ≥80%(100%Load) | |||||
Resp.Time | ≤2ms | |||||
Suit.Load | No load type restrictions, but motors and rectifying loads require derating. | |||||
Display | High-precision four-digit digital LED display for voltage, current, frequency, power, and power factor | |||||
Cooling method | Fan Cooling | |||||
Noise level | ≤55dB | |||||
Output protection | Complete protection functions and alarm devices for overvoltage, overcurrent, short circuit, and overheating. | |||||
Reliability | MTBF | 1.0×105h | ||||
MTTR | 0.5h | |||||
Env | Work.Temp | -25℃-55℃ | ||||
Rel.Hum | 0-90% (non-condensing) | |||||
Altitude | ≤2000 meters | |||||
Power supply model | LZ13-0.5K | LZ13-1K | LZ13-3K | LZ13-5K | LZ13-10K | |
Rated capacity | 0.5VA | 1VA | 3VA | 5VA | 10VA | |
Circuit diagram | IGBT/PWM Pulse Width Modulation Method | |||||
Enter | Ph.Num | 1- Phase | ||||
Volt | 220V±10% | |||||
Freq | 50Hz/60Hz±10% | |||||
Output | Ph.Num | 1- Phase | ||||
Wfm | Pure Sine Wave | |||||
Phase voltage | Rated 115V; adjustable range 0-150V (continuously variable) | |||||
Line voltage | Rated 200V; adjustable range 0-260V (continuously variable) | |||||
Load Reg.Rate | ≤1% | |||||
Rated Freq | 400Hz | |||||
Adj.Range | 300Hz-500Hz Continuously Adjustable (Custom frequencies available) | |||||
Freq.Stab | Rated Frequency ≤0.1%; Adjustment Range ≤0.01% | |||||
Wfm.Dist (THD) | THD≤3% | |||||
Eff | ≥80%(100%Load) | |||||
Resp.Time | ≤2ms | |||||
Suit.Load | No load type restrictions, but motors and rectifying loads require derating. | |||||
Display | High-precision four-digit digital LED display for voltage, current, frequency, power, and power factor | |||||
Cooling method | Fan Cooling | |||||
Noise level | ≤55dB | |||||
Output protection | Complete protection functions and alarm devices for overvoltage, overcurrent, short circuit, and overheating. | |||||
Reliability | MTBF | 1.0×105h | ||||
MTTR | 0.5h | |||||
Env | Work.Temp | -25℃-55℃ | ||||
Rel.Hum | 0-90% (non-condensing) | |||||
Altitude | ≤2000 meters | |||||
Power supply model | LZ33-15K | LZ33-20K | LZ33-30K | LZ3-45K | LZ33-60K | LZ33-100K | |
Rated capacity | 15KVA | 20KVA | 30KVA | 45KVA | 60KVA | 100KVA | |
Circuit diagram | IGBT/PWM Pulse Width Modulation Method | ||||||
Enter | Ph.Num | 3- Phase | |||||
Volt | 380V±10% | ||||||
Freq | 50Hz/60Hz±10% | ||||||
Output | Ph.Num | 3-phase 4-wire | |||||
Wfm | Pure Sine Wave | ||||||
Phase voltage | Rated 115V; adjustable range 0-150V (continuously variable) | ||||||
Line voltage | Rated 200V; adjustable range 0-260V (continuously variable) | ||||||
Load Reg.Rate | ≤1% | ||||||
Rated Freq | 400Hz | ||||||
Adj.Range | 300Hz-500Hz Continuously Adjustable (Custom frequencies available) | ||||||
Freq.Stab | Rated Frequency ≤0.1%; Adjustment Range ≤0.01% | ||||||
Wfm.Dist (THD) | THD≤3% | ||||||
Eff | ≥80%(100%Load) | ||||||
Resp.Time | ≤2ms | ||||||
Suit.Load | No load type restrictions, but motors and rectifying loads require derating. | ||||||
Display | High-precision four-digit digital LED display for voltage, current, frequency, power, and power factor | ||||||
Cooling method | Fan Cooling | ||||||
Noise level | ≤55dB | ||||||
Output protection | Complete protection functions and alarm devices for overvoltage, overcurrent, short circuit, and overheating. | ||||||
Reliability | MTBF | 1.0×105h | |||||
MTTR | 0.5h | ||||||
Env | Work.Temp | -25℃-55℃ | |||||
Rel.Hum | 0-90% (non-condensing) | ||||||
Altitude | ≤2000 meters | ||||||