INTRODUCE
A DC/DC high voltage input power supply is a device that converts a high voltage DC power supply into a DC power supply of a different voltage level. They are widely used in a variety of applications
FEATURES
lUltra-small size, save space
lInput and output isolation
lUniversal input voltage: 85-264VAC/100-370VDC
lOutput overcurrent protection, short circuit protection
lThis series of products are widely used in industry, power, instrumentation, communication, smart home and other fields
SPECIFICATIONS
Project  | Condition  | Minimum  | Typical Value  | Maximum  | |
 Input voltage range  | AC input  | 85VAC  | 230VAC  | 264VAC  | |
DC input  | 100VDC  | 310VDC  | 370VDC  | ||
 Input Current  | 230VAC  | /  | /  | 220mA  | |
115VAC  | /  | /  | 380mA 
  | ||
Output voltage accuracy 
  | Single output  | /  | ±2%  | /  | |
Dual output, balanced load*2  | Main Road  | ±2%  | |||
Auxiliary Road  | /  | ±10%  | /  | ||
Linear regulation rate  | Full load  | /  | ±1% 
  | /  | |
Load regulation rate  | Single channel, 10%-100% load  | /  | ±3%  | /  | |
 Dual output, 10%-100% balanced load*2  | Main Road  | ±3%  | |||
Auxiliary Road  | ±10%  | ||||
Output ripple and noise*  | 20MHz bandwidth (peak-to-peak) 
 
  | /  | 100mV 
  | /  | |
Short circuit protection  | Can be short-circuited for a long time, self-recovery  | ||||
Output overcurrent protection  | ≥110%Io, self-recovery  | ||||
Minimum load  | 0  | /  | /  | ||
Power-off hold time  | /  | 20ms  | /  | ||
Operating temperature  | -40℃  | /  | +70℃  | ||
Storage temperature  | -40℃  | /  | +105℃  | ||
Storage humidity  | /  | /  | 95%RH  | ||
Switching frequency  | /  | 65kHz  | /  | ||
Insulation voltage  | Input to output, test 60s, ≤5mA  | 3000VAC  | /  | /  | |
MTBF  | MIL-HDBK-217F@25℃  | 215000h  | /  | /  | |
Note: *1 Ripple and noise are tested using the parallel line test method (the oscilloscope probe is close to the test, and a 10μF high-frequency low-resistance electrolytic capacitor and a 0.1μF ceramic capacitor are connected in parallel at the close test point). *2. Balanced load means that the output load of the main circuit and the auxiliary circuit changes in the same proportion.  | |||||
MODEL LIST
Model  | Input voltage range  | Output Power  | Rated output voltage( V )  | Rated output current( mA )  | Size (Length * Width * Height)  | 
IPS15-V2S03  | 
 
 
 
 
 85-264VAC/100-370VDC 
 
 
 
 
  | 10W  | 3.3VDC  | 3000mA  | 62.0*45.0*22.5 MM  | 
IPS15-V2S05  | 
 
 
 
 
 
 
 
 
 15W  | 5VDC  | 3000mA  | ||
IPS15-V2S09  | 9VDC  | 1670mA  | |||
IPS15-V2S12  | 12VDC  | 1250mA  | |||
IPS15-V2S15  | 15VDC  | 1000mA  | |||
IPS15-V2S24  | 24VDC  | 625mA  | |||
IPS15-V2D05  | +5VDC  | 1500mA  | |||
IPS15-V2D12  | +12VDC  | 625mA  | |||
IPS15-V2D15  | +15VDC  | 500mA  | |||
IPS15-V2D24  | +24VDC  | 312 mA  | |||
IPS15-V2E0505  | 5VDC  | 2200mA  | |||
IPS15-V2E0512  | 5VDC  | 2000mA  | |||
IPS15-V2E0515  | 5VDC  | 2000mA  | |||
IPS15-V2E0524  | 5VDC  | 2000mA  |