Introduce:
This series of products is a high-precision single-output programmable linear DC power supply with high-precision, low ripple, adjustable, and multiple operating modes.
Feature:
●Window List sequence test technology, can store/call 100 sets of voltage and current data.
●Multiple power-on modes are optional.
●Compatible with standard Modbus and SCPl protocols.
●Optional display of power or load resistance value, with low resistance measurement function.
●Multiple protection functions such as overload, reverse polarity protection, overvoltage protection, overcurrent protection, overtemperature protection, etc.
●Multiple trigger sources (command, level, pulse, external) trigger mode selection.
●VSelf voltage automatic calibration function to reduce the deviation from the set voltage value.
●Constant current priority setting.
●Standard rear RS232 interface, optional RS485 interface: optional USB interface: optional Ethernet interface.
●Optional buzzer, suitable for a variety of different occasions.
●High resolution, high accuracy.
Specification:
| Brand | IDEALPLUSING | |||||
| Product Name | 6-bit blue screen programmable cabinet DC power supply | |||||
| Model | IPS-ATDM1560 | IPS-ATDM3020 | IPS-ATDM3030 | IPS-ATDM6010 | IPS-ATDM6015 | IPS-ATDM8011 | 
| Rated dc output (0℃~40℃) | ||||||
| Voltage | 0~15VDC | 0~30VDC | 0~30VDC | 0~60VDC | 0~60VDC | 0~80VDC | 
| Current | 0~60A | 0~20A | 0~30A | 0~10A | 0~15A | 0~11A | 
| Over-voltage protection | 0.1~33V | 0.1~33V | 0.1~33V | 0.1~65V | 0.1~65V | 0.1~65V | 
| Over-current protection | 0.1~4A | 0.1~6A | 0.1~11A | 0.1~4A | 0.1~6A | 0.1~6A | 
| Voltage output | ||||||
| Power supply effect | ≤0.01%+4mV | |||||
| Loading effect | ≤0.01%+5mV | |||||
| Recovery time | ≤1.5ms (50% load change) | |||||
| Ripple and noise | ≤2mVrms, 30mVpp | |||||
| Temperature coefficient | ≤300ppm/℃ | |||||
| Setting accuracy | ±(0.03% of reading + 10mv)(25±5℃) | |||||
| Set resolution | 0.1mA | |||||
| Current output | ||||||
| Power supply effect | ≤0.2%+3mA | |||||
| Loading effect | ≤0.2%+5mA | |||||
| Ripple and noise | ≤10mArms(i>3a) | |||||
| Setting accuracy | ±(0.3% of reading + 0.1% of fs)(25±5℃) | |||||
| Set resolution | 0.1mA | |||||
| Show | ||||||
| Voltage | 6 digits display | |||||
| Current | 6 digits display | |||||
| Voltage resolution | 1mV(6 digits ) | |||||
| Current resolution | 0.01ma (resolution 0.1ma above 10a) (6 digits) | |||||
| Reading accuracy | ±(0.02% of reading+5mv)(25±5℃); ±(0.1% of reading+0.1% of fs)(25 ±5℃) | |||||
| Protect | Overload protection, reverse polarity protection, over-voltage protection, over-current protection, over-temperature protection | |||||
| Lock keyboard | Have | |||||
| Programming interface | Standard RS232 interface, support SCPI and MODBUS instruction set, analog control interface ( optional ) | |||||
| Programming protocol | Compatible with modbus and scpi protocols | |||||
| Store recall | 100 groups | |||||
| Insulation | Between output terminal and housing or other terminals: ≥ 20MΩ / 500VDC | |||||
| Operating environment | Indoor use altitude: ≤2000m ambient temperature: 0℃~40℃ relative humidity: ≤80% Installation class: Ii pollution degree: 2 | |||||
| Storage environment | Ambient temperature: -10~70℃ relative temperature: ≤70% | |||||
| Power input | 220VAC±10%,50/60hz | |||||
| Appendix | User manual 1 copy, power cord 1 piece, host computer software CD 1 piece, RS232 interface cable 1 piece | |||||
| Size (without protective case) | 376(d)×215(w)×89(h)mm | |||||
| Weight | 5.5kg | |||||
Model list:
| Model | Output Peak Voltage(VDC) | Output Peak Current(AMP) | Output Peak Power (WATT) | Size (MM) | 
| IPS-ATDM1560 | 15VDC | 60A | 900W | 376×215×89MM | 
| IPS-ATDM3020 | 30VDC | 20A | 600W | 376×215×89MM | 
| IPS-ATDM3030 | 30VDC | 30A | 900W | 376×215×89MM | 
| IPS-ATDM6010 | 60VDC | 10A | 600W | 376×215×89MM | 
| IPS-ATDM6015 | 60VDC | 15A | 900W | 376×215×89MM | 
| IPS-ATDM8011 | 80VDC | 11A | 880W | 376×215×89MM | 
 
         
         
         
        